External connections, 5 external connections – Comtech EF Data CST-5000 User Manual
Page 49
![background image](/files/778811/content/doc049.png)
CST-5000 C-Band Satellite Terminal
Single Thread System Installation
Rev. 9
2–21
2.5 External Connections
Connections between the RFT and other equipment are made through six connectors.
These connectors are listed in Table 2-1, and their locations are shown in Figure 2-4. The
use of each connector is described in the following paragraphs.
Cables for connectors J3, J4, and J5 are supplied by EFData. A connector kit for the
remote connector, J6, is also supplied. All others must be supplied by the customer.
Table 2-1. Rear Panel Connectors
Name
Ref. Design.
Connector Type
Function
TX/IF IN
J1
TNC
TX IF INPUT (70 MHz)
TX/RF OUT
J2
Type N
5.845 to 6.425 GHz Out
RX/IF OUT
J3
TNC
RX IF OUT (70 MHz)
RX/RF IN
J4
Type N
3.620 to 4.200 GHz Input
PRIME PWR
J5
3- or 4-pin CIR
Prime Power Input
REMOTE
J6
26-pin CIR
Remote Interface
GND
ERDE GND
#10-32 Stud
Chassis Ground
Figure 2-4. RFT External Connections