B.3 Configuration Commands/Responses

Up
Converter
Freq Select

Command:
Response:


Status:
Response:

<add/UCF_nnnn.n'cr'
>add/UCF_nnnn.n'cr'
RF_OFF'cr''lf']

<add/UCF'cr'
>add/UCF_nnnn.n'cr''lf']

Where: nnnn.n = 5845.0 to 6425.0 MHz, in 2.5 MHz steps.

Down
Converter
Freq Select

Command:
Response:

Status:
Response:

<add/DCF_nnnn.n'cr'
>add/DCF_nnnn.n'cr''lf']

<add/DCF'cr'
>add/DCF_nnnn.n'cr''lf']

Where: nnnn.n = 3620.0 to 4200.0 MHz, in 2.5 MHz steps.

This command is not available with the single synthesizer
option.

RF Output

Command:
Response:

Status:
Response:

<add/RF_xxx'cr'
>add/RF_xxx'cr''lf']

<add/RF_'cr'
>add/RF_xxx'cr''lf']

Where: xxx = ON, WRM, or OFF.

The OFF command will keep the RF output turned off under
all conditions.

The WRM command is a conditional ON command instructing
the RF output to come on after the unit is warmed up and
meets stability requirements.

The ON command is an override, instructing the output to be
on and ignoring the warm start.

Up
Converter
Attenuator

Command:
Response:

Status:
Response:

<add/UCA_nn.n'cr'
>add/UCA_nn.n'cr''lf']

<add/UCA_'cr'
>add/UCA_nn.n'cr''lf']

Where: nn.n = 0.0 to 25.0 dB, in 0.5 dB steps.

Down
Converter
Attenuator

Command:
Response:

Status:
Response:

<add/DCA_nn.n'cr'
>add/DCA_nn.n'cr''lf']

<add/DCA_'cr'
>add/DCA_nn.n'cr''lf']

Where: nn.n = 0.0 to 21.0 dB, in 0.5 dB steps.

Advertising