Comtech EF Data CST-5000 User Manual

Page 67

Advertising
background image

CST-5000 C-Band Satellite Terminal

Redundant System Installation

Rev. 9

3–13


(3) Release pressure on the spring nut.

(4) Repeat Steps 5.b.(1) through 5.b.(3) for each spring nut.

c. Thread a 5/16-20 nut approximately 1-1/2 inch (38 mm) onto each threaded

rod. (This will ensure that the threaded rods will extend beyond the spring
nuts when installed.)


d. Place a 5/16 inch (8 mm) split lockwasher, 5/16 inch (8 mm) flat washer, and

flat fitting plate over each threaded rod.


e. One threaded rod at a time,

hold the washers and plate in
place on the threaded rod and
screw it into a spring nut, as
illustrated.

Notes:

1. Be sure to position

the flanges of the flat
fitting plates in the
grooves of the
unistruts.

2. Before tightening the

nuts on the threaded
rods, ensure that the
end of each rod is
screwed in until it
contacts the unistrut.
This ensures the rods
are threaded
completely through
the spring nuts.


Tighten each nut firmly.


f. Thread a 5/16-18 nut about 2

inches (5.1 cm) onto the end
of each threaded rod.




g. Slip a 5/16 inch (8 mm) split

lockwasher, 5/16 inch (8 mm)
flat washer, and flat fitting
plate (in that order) onto each
threaded rod.








6. Mount the RFTs as follows:

Advertising