Spar installation, 3 spar installation – Comtech EF Data CST-5000 User Manual

Page 45

Advertising
background image

CST-5000 C-Band Satellite Terminal

Single Thread System Installation

Rev. 9

2–17

2.3.3 Spar Installation

Note: The following process is for a typical installation. Custom systems may be ordered,
and are beyond the scope of this manual.

To install the RFT to a spar:

1. Set the unit on its side, with the mounting holes facing up.

2. Install the 8 inch (20.3 cm) unistruts as follows:

a. Position an 8 inch (20.3 cm) unistrut

(with the open side facing up) over
one set of the mounting holes on the
RFT.











b. Using four 1/4-20 x 1 inch bolts, 1/4

inch (6 mm) split lockwashers, and
1/4 inch (6 mm) flat washers, attach
an 8 inch (20.3 cm) unistrut to the
RFT.


Tighten the bolts firmly.


c. Repeat Steps 2.a. and 2.b. for the

second 8 inch (20.3 cm) unistrut.