Comtech EF Data CST-5000 User Manual
Page 41
![background image](/files/778811/content/doc041.png)
CST-5000 C-Band Satellite Terminal
Single Thread System Installation
Rev. 9
2–13
5. Install the threaded rods as follows:
a. Install two spring nuts in both 14”
unistruts mounted on the RFT.
Note: Ensure the spring nuts are
positioned over the outer holes in the
14 inch (35.6 cm) unistruts, as
illustrated.
b. To install each spring nut:
(1) Place the spring nut in the
unistrut channel, spring side
down, with its wide side parallel
with the unistrut channel.
(2) Press down on the spring nut to
compress the spring, and rotate
the nut 90
° (i.e., perpendicular to
the unistrut).
(3) Release pressure on the spring nut.
(4) Repeat Steps 5.b.(1) through 5.b.(3) for each spring nut.
c. Thread a 5/16-20 nut approximately 1-1/2 inch (1.27 cm) onto each threaded
rod. (This will ensure that the threaded rods will extend beyond the spring
nuts when installed.)
d. Place a 5/16 inch (8 mm) split lockwasher, 5/16 inch (8 mm) flat washer, and
flat fitting plate over each threaded rod.