Time-to-First-Fix (TTFF) Specifications

Typical values measured per ION-STD 101

Dynamics

¹Restricted by export laws
²Supported in software. From a hardware perspective, receiver should be
placed in a pressurized environment >12.2km (40,000 ft.)

Measurement Performance

Measurement Precision (RMS)

Raw C/A code:
Raw Carrier Phase
Noise:

7.50cm
L1: 0.7mm
L2: 0.9mm

RTK Positioning

– Multi-Frequency <40kms

1

(RMS)

Position (H):
Position (V):

+ 1cm +0.5ppm
+ 2cm +1ppm

1

Does not represent UHF radio modem range

Table continued on next page…

Cold Start

< 60 seconds

No valid Almanac or
Ephemeris data
available

Warm Start

< 50 seconds

Valid Almanac
available (less than
one year old)

Hot Start

< 20 seconds

Valid Ephemeris
available (less than
4 hours old)

Acceleration

up to 6g

Speed

< 515 m/s

1

(1,000 knots)

Altitude

< 18.3km

1,2

(60,000 ft)