Working with snmp, View traps, View alarm status via tenor ax icon – Quintum Technologies Tenor AX User Manual

Page 88: Working with snmp -8, View traps -8, View alarm status via

Advertising
background image

6-8

P/N 480-0062-00-10

Chapter 6: Advanced Topic: SNMP/IVR

Working with SNMP

View traps

You can view the traps HP Openview received from the Tenor AX unit as follows:

NOTE:

Ensure HP Openview is running.

1. From the HP Openview map where the Tenor AX units appear, right-click on the Tenor AX icon

for which you want to view traps and select Alarms.

2. From the Alarm Categories window, click on All Alarms. All traps (alarm messages) will be

listed in the order in which they occurred.

View Alarm Status via Tenor AX icon

Through the color of a Tenor AX icon on the HP Openview desktop, you can determine the alarm
state of the unit as well as view the corresponding alarms. Valid icon colors are listed below.

Green Icon. No Alarm indicated.

Red Icon. Critical Alarm (used for when HP Openview cannot communicate with the Tenor AX
or there is a severity level 1 alarm).

Orange Icon. Major Alarm (used for severity level 2 alarms).

Yellow Icon. Minor Alarm (used for severity level 3 alarms).

White Icon. Info Alarm (used for severity level 4 alarms).

View the alarms associated with a Tenor AX unit as follows:

NOTE:

Ensure HP Openview is running.

1. From the HP Openview desktop, identify the icon for the Tenor AX unit from which you would

like to view alarms.

2. According to the color of that icon, determine the alarm state from the list above.

3. To view the alarms associated with that icon, right-click from anywhere on the HP Openview

desktop and select Alarms. The All Alarms Browser window will appear, which contains the list
of alarms.