Rs-442a serial port – Verilink AS100 (896-502379-001) Product Manual User Manual

Page 103

Advertising
background image

Access System Centum Series User Manual

B-3

RS-442A Serial Port

RS-422A Category I signaling is provided through a female DB-25
connector per the RS-530 specification. With an external adapter cable,
the same signals are provided through a female DB-37 connector per the
RS-449 specification. The pin assignments are shown. Verilink cabling
is recommended:

458-501792-

0

1

5

D-type 25-pin (DB-25) male connectors at both ends

(in compliance with RS-530 specification). Fifteen feet long. Optional at
extra cost.

RS-530

(DB-25)

Connector

RS-449

(DB-37)
Adapter

Signal

To/From

Access System

100

15

5

Transmit Clock (A)

From

17

8

Receive Clock (A)

From

24

17

Ext. Transmit Clock (A)

To

2

4

Transmit Data (A)

To

3

6

Receive Data (A)

From

12

23

Transmit Clock (B)

From

9

26

Receive Clock (B)

From

11

35

Ext. Transmit Clock (B)

To

14

22

Transmit Data (B)

To

16

24

Receive Data (B)

From

4

7

Request to Send (A)

To

8

13

Data Carrier Detect (A)

From

5

9

Clear to Send (A)

From

20

12

Data Terminal Ready (A)

To

6

11

Data Set Ready (A)

From

19

25

Request to Send (B)

To

10

31

Data Carrier Detect (B)

From

13

27

Clear to Send (B)

From

23

30

Data Terminal Ready (B)

To

22

29

Data Set Ready (B)

From

7

19

Ground

------

Advertising