Serial port bert, Serial port bert -12 – Verilink AS100 (896-502379-001) Product Manual User Manual

Page 64

Advertising
background image

4-12

Access System Centum Series User Manual

Serial Port BERT

The Serial Port (DTE) BERT can be used as a part of many different test
configurations. It is most valuable with both the Local and Remote Serial
Port Loops activated (see page 4-10); the local end of the recommended
configuration is shown below.

The “Local” Errored Seconds are counted by the detector toward the left
side in the figure. The “Remote” Errored Seconds are counted by the
detector toward the right side.

WHEN TESTING IS COMPLETED, BE SURE TO TURN THE LOOP AND
BERT “OFF”.

Diagnostics

_Serial Port #1 (or 2)

iag. Menu,

/DOWN

to

display:

SP 1 (or 2) Diagnostics

_BERT.....: On

SELECT

to

display:

SP 1 (or 2) Diagnostics

_Loc ES...:_

∅∅∅∅∅

DOWN

and

SELECT

as

to display:

SP 1 (or 2) Diagnostics

_Rem ES...:_

∅∅∅∅∅

DOWN

and

ELECT

as

to display:

SP 1 (or 2) Diagnostics

_Sec/Test.:_

∅∅∅∅∅

DOWN

and

SELECT

as

to display: