Configuration Parameters

Access System Centum Series User Manual

3-15

requires special user cabling and a very specific DCE configuration.
Please refer to Appendi xC, Special Serial Port Cabling for more
information.

Int/Ext should be used for Serial Port #1 if the attached user DTE is
substantially far away from Centum Series and/or if Serial Port #1 is
to be used as the system’s master clock. See Timing Source (item
#12, above).

Int/Ext should be used for Serial Port #2 if the attached user DTE is
substantially far away from the Centum unit. The Centum unit will
provide RX-clock to the attached DTE and will accept TX-clock
from the DTE.

The Int/Ext setting requires a special DTE requires a special DTE
configuration or a modified cable. Please refer to Appen d ixC,
Special Serial Port Cabling
for more information.

Important Notes:

a. If Int/Ext timing has been selected for Serial Port #1 because

Serial Port #1 is to be used as the system’s master clock (see
item #12, above), the recommendation in Appendi xC must be
followed.

b. If excessive DTE cable distance is the only concern, consider the

following:

• Clocking problems appear as periodic (predictable) error

bursts.

Internal Serial Port timing should first be attempted with a

normal DTE configuration and a standard cable.

• If clocking problems occur, they can frequently be corrected

by using clock inversion (items #17 and #24, above) and
retaining the normal DTE configuration and the standard
cable.