Esf statistics definitions, Esf statistics definitions -2 – Verilink AS100 (896-502379-001) Product Manual User Manual

Page 68

Advertising
background image

5-2

Access System Centum Series User Manual

Framing Errors.

One or more frame alignment bit errors have been

detected. This does not mean that synchronization has been lost.

CRC6 Alar

m.

One or more CRC6 block errors have been detected. The

D4 framing does not include CRC6; Centum Series replaces that
parameter by counting the number of framing bit errors. The result is a
useful picture over time regarding D4 link performance.

BPV.

Bipolar Violations have been detected. This usually indicates that

a very weak or overly strong signal is being received from the network.

ESF Statistics
Definitions

Errored Second (ES).

Any occurrence of a Loss of Frame or a CRC6

error in a one-second period.

Failed Signal State (FSS).

Ten consecutive Errored Seconds.

Failed Second (FS).

Each second during the occurrence of a Failed

Signal State.

Severely Errored Second (SES

)

Three hundred twenty (320) or more

CRC6 errors in a one-second period.

Bursty Errored Second (BES).

More than one but less than 320 CRC6

errors in a one-second period.

Advertising