6-12

Access System Centum Series User Manual

Link Alarms and Statistics

The user has selected Link Alarms and Statistics from the terminal’s
Main Menu and is presented with the menu depicted below. This menu
provides access to Network and DSX-1 Alarms and Network diagnostics
(see Chapter 4, page 4-2 through page 4-6). Also see Chapter 5, Alarms
and Statistics,
on page 5-1.

Add 1 screen

Verilink Corporation Mar 18, 1995

Access System 150 T-1 Drop-and-Insert CSU/DSU 20:26:00

Unit ID: 30000000

System Alarms and Statistics

Network Interface (NI) Network Interface (NI) DSX-1 Interface

Alarms Diagnostics Alarms

State ErrSec State ErrSec

AIS No 00000 CSU Loop..: Off AIS No 00000

Red No 00001 NI LLB....: Off Red No 00000

Yel No 00000 NI RLB....: Off Yel No 00000

Ferr No 00001 PAYLD Loop: Off Ferr No 00000

CRC6 No 00001 DSX-1 Loop: Off CRC6 No 00000

BPV No 00000

LOS No 00001 Loop Ind...: Off

BER Pattern: 1 of 8

BERT.......: Off >> [E] to Insert BER Errors

Err Secs...: 00000

Sec/Test...: 00000

Reset Counters = [R]

Cursor Forward = [SPACE] Select Entry = [ENTER]

Cursor Back = [BACKSPACE] Return to Previous Menu = [X]

Advertising