Access System Centum Series User Manual

4-7

Line Loop

LLB causes a local line loop (at the Centum Series unit where the
command was entered). RLB causes a remote line loop (at the distant end
of a point-to-point circuit); RLB should not be attempted in an Integrated
Access, Fractional T1 environment.

The CSU is excluded from the test path in a Line Loop configuration.

In a point-to-point circuit, the LLB and RLB are useful for looping back
any testing initiated by the other end, such as Payload, Serial Port, or
DSX-1 BERTs or any externally generated testing.

In an Integrated Access, Fractional T1 circuit, LLB is useful for looping
back Serial Port or DSX-1testing initiated by any remote location.

WHEN TESTING IS COMPLETED, BE SURE TO TURN THE LOOP
“OFF”.

Diagnostics

_NI/DSX-1 Port

iag. Menu,

/DOWN

to

display:

NI/DSX-1 Diag.

NI LLB...:_On

DOWN

and

ELECT

as

to display:

NI/DSX-1 Diag.

NI RLB...:_On

DOWN

and

SELECT

as

to display:

OR