5-8

F r a m e S t a r t F S M

Figure 5.8

Performance Menu Tree

The parameters found on this menu are the same as on the Alarms menu tree,
except for the three additional parameters defined below.

CRCES

Sets the Cyclic Redundancy Check Errored Seconds (CRCES) threshold. A
CRC is a method of confirming the integrity of received data.

BES

Sets the Bursty Error Seconds (BES) threshold. A BES is a 1-second period
during which at least more than one but fewer than 320 CRC6 errors
occurred.

LOFC

The Loss of Frame Count (LOFC) represents the number of time a loss of
frame is declared. A loss of frame is declared after 2.5 seconds of continuous
loss of signal or OOF.

Maintenance Menu

The MAINTENANCE menu is used to perform loop test functions. From this
menu, Loop tests can be activated and cleared.

Net 24-hour

Perf

(read-only fields)

Performance

Rx
ES

SES

LOSS

OOFS
BPVS

CSS

RAS

AISS

UAS

CRCES

BES

LOFC