3-8

F r a m e S t a r t F S M

Figure 3.5

Performance/Summary Screen

In addition to the error parameters found in the Error Status and Alarm
Thresholds Table
on page 3-6,
the following error parameters are included on
the Network Performance/Summary table:

BES

Sets the Bursty Error Seconds (BES) threshold. A BES is a 1-second period
during which at least more than one but fewer than 320 CRC6 errors
occurred.

LOFC

The Loss of Frame Count (LOFC) represents the number of time a loss of
frame is declared. A loss of frame is declared after 2.5 seconds of continuous
loss of signal or OOF.

CRCES

Sets the Cyclic Redundancy Check Errored Seconds (CRCES) threshold. A
CRC is a method of confirming the integrity of received data.

Beneath the Performance/Summary table are two buttons: “Performance 24
Hour” and “Performance 30 Day.” Clicking on either of these will display a
detailed summary of error events that have occurred during each 15-minute
interval of the past 24 hours (Figure 3.6) or during each 24-hour interval of
the past 30 days (Figure 3.7). The error parameters are the same as those
found on the Performance/Summary table. Representations of these screens
are provided below.