Current pin status, Dtr alarm control and status table, 10/100 ethernet (ip service details) screen – Verilink FrameStart FSM (34-00299.E) Product Manual User Manual

Page 37: 10/100 ethernet (ip service details) screen -13

Advertising
background image

W e b S e r v e r I n t e r f a c e

3-13

DTE on the Serial interface. If set to “Forced True,” RTS is always perceived
as “On.”

Values: Normal, Forced True
Default: Normal

RTS/CTS Delay

The Request To Send/Clear To Send parameter determines how long the unit
waits before it changes the level of CTS to match RTS when the CTS
parameter is set to “Internal.”

Values: Normal (~30 ms delay), Long (~100 ms delay)
Default: Normal

Flow Control

Selects the type of flow control to be used if the port is asynchronous.

Values: None, Xon/Xoff, RTS/CTS
Default: None

Current Pin Status

The Current Pin Status, which shows the state of the RS-232 pins, is also
displayed on the Serial interface screens.

DTR Alarm Control and Status Table

In addition to the configurable fields, the Serial screen displays a table that
lets you set the Data Terminal Ready (DTR) Alarm Control parameters and
view the current DTR Alarm Status.

Choices for DTR Alarm Control are “Enable” and “Disable”; the default
setting is “Disable.” Setting DTR Alarm Control to “Enable” allows the unit
to go into alarm on a loss of DTR, which occurs when the Serial port detects
that the DTR signal is low. The DTR Status field indicates the current state of
the DTR alarm.

10/100 Ethernet (IP Service Details) Screen

The 10/100 Ethernet (IP Service Details) screen (Figure 3.9) lets you
configure the IP parameters described below.