W e b S e r v e r I n t e r f a c e

3-41

Trap IP Address

Accepts the IP address of a network device where alarm reporting traps are to
be sent.

The unit detects and reports T1 network alarms and provides several options
for reporting them, one of which is SNMP traps. When a network alarm
occurs, the unit sends a trap message to as many as eight destinations on the
user’s network. The unit will report each alarm by transmitting an SNMP
“trap” to each non-zero Trap IP address.

Diagnostics Screen

The Diagnostics screen (Figure 3.29) provides a table for viewing the current
settings for the test and maintenance functions performed on the available
interfaces. This screen shows an upper-level view of all the interfaces so you
can see if any port is under test, and if so, view the results. You may change
Diagnostic parameters through the Test Details screen, which is accessed from
a button on the Diagnostics screen. The properties of the Diagnostics table are
described in the paragraphs below.

Figure 3.29

Diagnostics Screen

Description

Describes the type of interface selected for testing.

Loop Type

Describes the type of loop test (if any) performed on the selected interface.

Setting

Displays the bandwidth on which you wish to perform the BERT.

Pattern

Specifies the pattern to be transmitted during a test for the selected port.

Length

Displays the length of time for which the test should run for the selected
interface.

State

Displays the current test state for the selected interface.

Elapsed Time

Displays the time elapsed since a timed test began or, if completed, the total
test time.