Configuration menu, Tcp/ip configuration menu, Configuration menu -11 – Verilink FrameStart FSM (34-00299.E) Product Manual User Manual

Page 129: Tcp/ip configuration menu -11

Advertising
background image

F r o n t P a n e l L C D I n t e r f a c e

5-11

Length

Lets you specify the length of time that the BERT should run for the selected
interface.

Values: 15 Minutes, 30 Minutes, 1 Hour, 24 Hours, Continuous
Default: 15 Minutes

Sync

Display-only field shows the state of pattern sync during a BERT. If no
BERT is in progress, “No Test” is displayed. If a BERT is active but the
receiver is not in pattern sync, “No Sync” is displayed. If the receiver is in
pattern sync, “In Sync” is displayed.

Elapsed

Display-only field shows the amount of time (in seconds) that has elapsed
since a BERT began or, if completed, the total test time.

Bit Errors

This display-only field shows the number of bit errors detected since the
BERT began or since error statistics were last cleared.

ES

Display-only field shows the number of asynchronous errored seconds
detected since the BERT began or since error statistics were last cleared. This
parameter includes bit error seconds and sync loss seconds.

% EFS

Display-only field shows what percent of the total test time ran error free.
This ratio is derived from the number of error free seconds divided by the
number of seconds accumulated in Elapsed Time.

Cmd

Lets you control basic aspects of the BERT performed, including the injection
of errors during test.

Values: Stop, Reset, Error Inject, Start
Default: Stop

Configuration Menu

The Configuration menu lets you configure the parameters of the various
interfaces.

Figure 5.10

Configuration Menu Tree

TCP/IP Configuration Menu

The TCP/IP CONFIG menu lets you configure the unit’s IP parameters. Use
the

SCROLL

button to display the desired configuration parameter, and then

press the

SELECT

button to activate the configuration function.

Configuration

Serial Config

Net Config

TCP/IP Config

Supv Config

Advertising