Displays the total number of bit errors detected since the test began or since
error statistics were last cleared.

ES (Errored Seconds)

Displays the number of asynchronous errored seconds that have been detected
since the test began or since error statistics were last cleared. This parameter
includes bit error seconds and sync loss seconds.

%EFS

Displays what percent of the total BERT time ran error free. This ratio is
derived from the number of error-free seconds divided by the number of
seconds accumulated in Elapsed Time.

Test Details Screens

The Test Details screens let you set some test parameters and view other read-
only parameters. This screen is also used to initiate a BERT or Loop Test.
The Network Interface Test Details screen is shown in Figure 3.30 and the
Serial Interface Test Details screen is shown in Figure 3.31.

Figure 3.30

Network Interface Test Details Screen

BERT Table on Network Interface Test Details Screen

The BERT table lets you set the test parameters described below.

Setting

Displays the bandwidth on which you wish to perform the BERT. The
available values for this parameter depend on which interface is selected.

Values: Idle, Channels 1–24, Net, Use Service
Default: Net

Service

Selects the channels with a service to BERT. (Refer to Figure 3.12 on
page 3-16.
) (This parameter only appears on Network screens.)