Overview

Verilink QUAD/IMUX User Manual

1-5

Figure 1-2 Multiline shelf “A” Bus Segmentation

Module Placement

Each Inverse Multiplexer application must have sole use of Data
Bus A, or a Bus A segment. The first QUAD 2164 module in any bus
island (carrying the first four T1s or E1s) must be installed in an
odd-numbered slot
.

The second QUAD 2164 module in any bus island, carrying the
second four T1s or E1s, must be installed in an even-numbered
slot. The IMUX 2160 module may be placed in an odd or even
numbered slot.

Maximized MLS

2200 Installation

Using the MLS 2200, you can install and configure up to six user
applications.

Figure 1-3

shows a shelf with a maximized

installation using multiple configurations.

Figure 1-3 MLS 2200 Application Support

IMUX

QUAD

QUAD

QUAD

QUAD

QUAD

QUAD

QUAD

A1

A2

A3

A4

A5

IMUX

IMUX

IMUX

IMUX

IMUX

Single 6 or 8 Mbit/s

Single 6 or 8 Mbit/s

Single 6 or 8 Mbit/s

Single 12 Mbit/s or 16

Dual 6 or 8 Mbit/s or

Slots 1 & 2

Slots 3 & 4

Slots 5 & 6

Slots 7,8, & 9

Slots 10, 11, 12 & 13

application

application

application

Mbit/s application

single 12 or 16 Mbit/s

application