E1 Configuration Menus

Verilink QUAD/IMUX User Manual

3-7

Figure 3-5 E1 Timing Options Menu

Table 3-5

E1 Timing Options Menu

Field Name

Description

PC (Primary)

SC (Secondary)

TC (Tertiary)

Source—Enter the slot of the module which will be the timing source. (This includes

the option of setting your QUAD 2164 as the timing source for the shelf.)

Select a primary timing source “PC”, also the secondary “SC” and tertiary timing

sources “TC”. The latter two sources provide a backup in case the primary source

fails.

PS

Primary Synchronization—Choose one of the following as your primary source for

time synchronization.

• NET 1: Use this option to synchronize timing to E1 port 1.

• NET 2: Use this option to synchronize timing to E1 port 2.

• NET 3: Use this option to synchronize timing to E1 port 3.

• NET 4: Use this option to synchronize timing to E1 port 4.

• INTERNAL: Selects the internal clock as your timing source.

• EXTERNAL: Selects an external clock as your timing source.

• 5) DAT 1: Not available on the QUAD 2164.

• 6) DAT 2: Not available on the QUAD 2164.

SS

Secondary Synchronization—Use this option to specify an alternate source of timing

for synchronization purposes. In the event that the primary source is unavailable, this

source will be used.

• NET 1: Use this option to synchronize timing to E1 port 1.

• NET 2: Use this option to synchronize timing to E1 port 2.

• NET 3: Use this option to synchronize timing to E1 port 3.

• NET 4: Use this option to synchronize timing to E1 port 4.

• INTERNAL: Selects the internal clock as your timing source.

• EXTERNAL: Selects an external clock as your timing source.

• 5) DAT 1: Not available on the QUAD 2164.

• 6) DAT 2: Not available on the QUAD 2164.

-- QUAD 2164 CONFIGURATION MENU (TIMING OPTIONS)--

-- QUAD 2164 CONFIGURATION MENU (TIMING OPTIONS)--

-- QUAD 2164 CONFIGURATION MENU (TIMING OPTIONS)--

-- QUAD 2164 CONFIGURATION MENU (TIMING OPTIONS)--

Current shelf timing source: Card 1, INT

Current shelf timing source: Card 1, INT

Current shelf timing source: Card 1, INT

Current shelf timing source: Card 1, INT

Source Slot Number Synchronization Auto Restore

Source Slot Number Synchronization Auto Restore

Source Slot Number Synchronization Auto Restore

Source Slot Number Synchronization Auto Restore

PRIMARY PC) 2 PS) INT PA) YES

PRIMARY PC) 2 PS) INT PA) YES

PRIMARY PC) 2 PS) INT PA) YES

PRIMARY PC) 2 PS) INT PA) YES

SECONDARY SC) 2 SS) INT SA) YES

SECONDARY SC) 2 SS) INT SA) YES

SECONDARY SC) 2 SS) INT SA) YES

SECONDARY SC) 2 SS) INT SA) YES

TERTIARY TC) 2 TS) INT TA) YES

TERTIARY TC) 2 TS) INT TA) YES

TERTIARY TC) 2 TS) INT TA) YES

TERTIARY TC) 2 TS) INT TA) YES

R) Receive clock from shelf: YES

R) Receive clock from shelf: YES

R) Receive clock from shelf: YES

R) Receive clock from shelf: YES
X) exit this screen

X) exit this screen

X) exit this screen

X) exit this screen

Advertising