Restore defaults, Restore defaults -9 – Verilink QUAD/IMUX (880-502392-001) Product Manual User Manual

Page 61

Advertising
background image

T1 Configuration Menus

Verilink QUAD/IMUX User Manual

4-9

Restore Defaults

Restores the factory default settings. See Appendix A, "

Default

Configuration

" for the default values.

SS

Secondary Synchronization—Use this option to specify an alternate source of

timing for synchronization purposes. In the event that the primary source is

unavailable, this source will be used.

• NET 1: Use this option to synchronize timing to T1 port 1.

• NET 2: Use this option to synchronize timing to T1 port 2.

• NET 3: Use this option to synchronize timing to T1 port 3.

• NET 4: Use this option to synchronize timing to T1 port 4.

• INTERNAL: Selects the internal clock as your timing source.

• EXTERNAL: Selects an external clock as your timing source.

TS

Tertiary Synchronization—Use this option to specify an alternate source of timing

for synchronization purposes. In the event that the primary and secondary source

are unavailable, this source will be used.

• NET 1: Use this option to synchronize timing to T1 port 1.

• NET 2: Use this option to synchronize timing to T1 port 2.

• NET 3: Use this option to synchronize timing to T1 port 3.

• NET 4: Use this option to synchronize timing to T1 port 4.

• INTERNAL: Selects the internal clock as your timing source.

• EXTERNAL: Selects an external clock as your timing source.

PA (Primary)

SA (Secondary)

TA (Tertiary)

Auto Restore—Selects which timing source will be used when the primary timing

source fails, restores, and then remains viable for a period of 60 seconds.

For example, if the primary source fails, the secondary source becomes the timing

source. When the primary source is back in service, and the Auto Restore option is

set to Yes, the primary source resumes as the QUAD 2164 module’s timing source.

If the Auto Restore option is set to No, the secondary source remains the timing

source until you manually set the primary source’s Auto Restore option to Yes.

R

Receive clock from shelf—Indicates whether the QUAD will receive its timing signal

from the source used by the shelf or derive timing independently of all other

modules. For QUAD/IMUX applications, this option

must

be set to Yes.

X

Exit this menu