Table 2 Power supply specifications

Item Description

Rated voltage range

PSR650-A: 100 VAC to 240 VAC; 50 or 60 Hz
PSR650-D: –48 VDC to –60 VDC

Maximum input current

PSR650-A: 10 A
PSR650-D: 25 A

Maximum power for a
single power supply

650 W

Dimensions (H × W × D)

40 × 165 × 350 mm (1.57 × 6.50 × 13.78 in)

Power supply slot

Two slots, and AC and DC power supplies cannot be inserted in the same slot at
the same time.

System power
consumption range

EWPX1WCMB0 main control board:
104 W to 233 W

EWPX1WCMD0 main control board:
136 W to 309 W

Hot swapping

Supported

NOTE:

Hot swapping means to power turn off the power switch before and then unplug a

PSU when the access controller has multiple PSUs while, without interrupting
ensuring the normal operation of the access controller; check that the power switch

is off before plugging a PSU, and then power turn on the power switch.

Redundancy Supported

LED

There is a power status LED above the power supply switch. Green means the
power supply operates properly, and red means the power supply is faulty.

WARNING!

The WX6103 supports both AC power input and DC power input. You can use AC or DC PSUs as
needed. Different types of PSUs cannot be used on the same WX6103 access controller.

The minimum system power consumption described in

Table 2

is obtained when one main control

board is installed and the switch interface board runs with no load. The maximum system power

consumption is obtained when two main control boards are installed and the switch interface board
runs with full load.

Figure 3 Front panel of the PSR650-A

1

2

3

4

1: Power socket

2: LED

3: Power switch

4: PSU handle

Advertising