Leds on the main control board panel – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 17

Advertising
background image

9

If the access controller has two main control boards working in active-standby mode, pressing the

reset button on the active main control board causes the system to switch to the standby main control

board. This results in a transient service interruption.

If the access controller has two main control boards, pressing the reset button on the standby main

control board causes the standby main control board to reboot without affecting system operation.

CAUTION:

When you press the reset button to restart the access controller, any unsaved configuration changes will
be lost.

Do not press the reset button while the access controller is rebooting or accessing the CF card or USB
device, as this may damage the file system of the access controller.

LEDs on the main control board panel

Table 9 Description of the LEDs on the main control board panel

LEDs Status

Meaning

Off

The board is out of position.

RUN
(Green)

Blinking

The board is operating normally.

Off

The board is out of position or working normally.

SLOT0 to SLOT2

ALM
(Red)

On

The board is faulty.

On

The fans are operating normally.

OK
(Green)

Off

At least one fan is faulty or out of position.

On

At least one fan is faulty or out of position.

FAN

FAIL
(Red)

Off

The fans are operating normally.

On

The board is in active state.

ACTIVE

ACTIVE
(Green)

Off

The board is in standby state.

Figure 9 LEDs on the EWPX1WCMB0

1

2

3

4

5

1: Slot 0 status LEDs

2: Slot 1 status LEDs

3: Slot 2 status LEDs

4: Fan status LEDs

5: ACTIVE LED