10

Figure 10 LEDs on the EWPX1WCMD0

1: Slot 0 status LEDs

2: Slot 1 status LEDs

3: Slot 2 status LEDs

4: Fan status LEDs

5: ACTIVE LED

Active-standby switchover of the main control boards

The WX6103 can be equipped with two main control boards, one in active state and the other in standby

state. When the active board becomes faulty, the standby board immediately takes over to ensure the

normal operation of the access controller. This process is known as active-standby switchover.
Any of the following situations will trigger an active-standby switchover of the main control boards:

The active main control board becomes faulty.

The active main control board is unplugged.

Switch interface board

The switch interface board provides twenty-four 10/100/1000Base-TX Gigabit electrical Ethernet ports,
and four SFP combo ports or two XFP ports (depending on the 10GE interface module used on the switch

interface board). Ports 21 through 24 of the twenty-four electrical Ethernet ports are combo ports.

Switch interface board specifications

Table 10 Technical specifications for the EWPX1G24XA

Item Description

CPU PPC,

400

MHz

Boot ROM

512 KB

SDRAM 256

MB

Dimensions (H × W × D)

45.2 × 376.7 × 354.5 mm (1.78 × 14.83 × 13.96
in)

Maximum power consumption

65 W

Connector type

RJ-45/LC

Number of interfaces

24 + 2

Interface speed

Electrical ports: 10/100/1000 Mbps

Optical ports: 1000 Mbps