H3C Technologies H3C WX6000 Series Access Controllers User Manual
Page 77

69
| Change The HyperTerminal's Baudrate Accordingly |
|---------------------------<Baudrate Avaliable>------------------------- |
|<1> 9600(Default)* |
|<2> 19200 |
|<3> 38400 |
|<4> 57600 |
|<5> 115200 |
|<0> Exit |
==========================================================================
Enter your choice(0-5):
Step2
Select an appropriate baud rate. For example, select 5 for 115200 bps. The following information
appears:
Baudrate has been changed to 115200 bps.
Please change the terminal's baudrate to 115200 bps, press ENTER when ready.
The serial interface baud rate of the access controller has been changed to 115,200 bps while that of the
terminal is still 9,600 bps, the access controller and the terminal cannot communicate with each other.
Change the baud rate to 115,200 bps in HyperTerminal.
Step3
Disconnect the terminal connection in HyperTerminal, as shown in
:
Figure 49 Disconnect the terminal connection
Step4
Choose File > Properties. In the Properties dialog box, click Configure… and select 115,200 in the Bits
per second drop-down list.