The following table lists the environmental criteria for the Profile XP Media Platform,
RAID storage Chassis, and the PAC216.
Characteristics
Description
Operating Temperature
Requirement:
10
° to 40°C
Storage Temperature
Requirement:
-40
° to 65°C
Operating Altitude
Requirement:
To 10,000 feet
Supplemental Data:
IEC 950 compliant to 2000 meters
Storage Altitude
Requirement:
To 40,000 feet
Mechanical Shock
Supplemental Data:
Class 5 (30G) Grass Valley 001131500
Random Vibration
Requirement:
Operational: Class 6 Grass Valley 001131500
Requirement:
Non-Operational: Class 5 Grass Valley 001131500
Transportation
Requirement:
Grass Valley 001131500
Equipment Type
Supplemental Data:
Information Technology
Equipment Class
Supplemental Data:
Class 1
Installation Category
Requirement:
Category II Local level mains, appliances, portable
equipment, etc.
Pollution Degree
Requirement:
Level 2 operating environment, indoor use only.
Relative Humidity
Requirement:
Operating 80% from +30
° to +40°C
Non-Operating 90% from +30
° to +60°C
Do not operate with visible moisture on the circuit