Grass Valley Profile XP Aug 16 2004 User Manual
Page 84

Chapter 3 Working with RAID Storage Using GVG Disk Utility
84
Profile XP System Guide
23 July 2004
The Binding LUN dialog box opens showing all unbound disks for the controller
listed in the Available Disk list.
4. Select Hot Spare using the LUN TYPE drop-down box.
5. Select the disk(s) to be used as hot spares, then click the add button
to add
them to the Selected Disks list.
NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click
Identify Disks.
This causes the disk drive LED to flash.
6. Click
OK
to close the Binding LUN… dialog box and begin the binding process.
The Progress Report dialog box opens, showing the status of the binding process.
7. Repeat step 3 through step 6 to bind additional hot spare disks modules on other
controllers as needed.
8. Upon 100% completion, click
Close
in Progress Report window.