Chapter 3 Working with RAID Storage Using GVG Disk Utility

84

Profile XP System Guide

23 July 2004

The Binding LUN dialog box opens showing all unbound disks for the controller
listed in the Available Disk list.

4. Select Hot Spare using the LUN TYPE drop-down box.

5. Select the disk(s) to be used as hot spares, then click the add button

to add

them to the Selected Disks list.

NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click

Identify Disks.

This causes the disk drive LED to flash.

6. Click

OK

to close the Binding LUN… dialog box and begin the binding process.

The Progress Report dialog box opens, showing the status of the binding process.

7. Repeat step 3 through step 6 to bind additional hot spare disks modules on other

controllers as needed.

8. Upon 100% completion, click

Close

in Progress Report window.