15  Troubleshooting

SMA Solar Technology AG

122

HoMan_Portal-BA-en-17

User Manual

The SMA radio-controlled
socket does not switch the
dishwasher on even though
start-up detection is activated.

For the Start-up detection function, the SMA radio-controlled
socket must have at least firmware version 12.12.111.R. You can
read off the firmware version via the parameter Software
package
(see Section 8.5, page 55).

Corrective measures:

1. If the SMA radio-controlled socket has a firmware version

lower than 12.12.111.R, ensure that the automatic
software update is activated for the devices in the PV system
(see Section 8.8, page 57). This way, the
SMA radio-controlled socket will receive the latest firmware
version within 24 hours.

2. If you had already configured start-up detection before the

firmware update of the SMA radio-controlled socket,
proceed as follows once the firmware update has been run
successfully:

• Call up the load properties of the dishwasher

(see Section 9.3.1, page 65).

• Select [Edit] and then immediately [Save]. This way,

the settings for start-up detection will be transmitted to
the SMA radio-controlled socket again.

Problem

Cause and corrective measures