9  Load Control

SMA Solar Technology AG

70

HoMan_Portal-BA-en-17

User Manual

9.3.10 Entering the Minimum Switch-Off Time

The minimum switch-off time is the minimum time the connected load must remain switched off,
for example, to prevent overheating or enable fault-free restarting.

Requirement:

☐ The connected load must be program-controlled (see Section 9.3.5).

Procedure:

• Enter the minimum switch-off time in the Minimum switch-off time text field.

9.3.11 Assigning SMA Radio-Controlled Sockets

For the following purposes, you must assign the SMA radio-controlled socket to the load to which it
is connected:

• to have the load controlled by the Sunny Home Manager
• to enable the load data to be stored by the Sunny Home Manager

If the load was temporarily not assigned to any SMA radio-controlled socket, corresponding data
gaps will appear in the consumption diagrams. The consumption data can always be called up on
the load itself, even if the load is now controlled by a different SMA radio-controlled socket.

Procedure:

• In the drop-down list SMA radio-controlled socket, select the SMA radio-controlled socket to

which the load is connected. By default, no SMA radio-controlled socket is assigned to the load.
If the desired SMA radio-controlled socket is already assigned to a different load, a "*" will be
displayed in front of the name of the SMA radio-controlled socket. To enable the
SMA radio-controlled socket to be reassigned, you must first remove the assignment of the
SMA radio-controlled socket from the profile of the other load.