4.2.10 ALARM 3002 (EMERGENCY STOP)

Table 4.12

Cause of Trouble

Emergency stop button
depressed, or, machine

end LS is out of place.

Failure of FC230B or

Drop of +24 V power
voltage

Check Method

ensuring

signal #3500

O

(during emergency stop), check
continuity of emergency stop button or
machine end LS shown below. For

connection, refer to connection

diagram prepared by machine
manufacturer.

FC230B

f

CN27-10,11

M A C H I N E

END LS

I

MACHINE END

RELEASE

This FC230 failure if alarm 3002 lights
even at #3500

= 1

Check +24 VDC power. If the voltage is
below +20 V, it indicates possible trouble.

Solution

Reset the emergency stop
button. Release it from

machine end LS according

to instruction manual
prepared by machine tool
manufacturer.

Replace FC230B or
Contact your YASKAWA
representative.

Replace

or

(power supply

unit).
Contact your YASKAWA
representative.