Setting and adjustment of each module, Cent’d) – Yaskawa i80M Maintenance Manual User Manual
Page 206

7.
SETTING AND ADJUSTMENT OF EACH
MODULE
(Cent’d)
Model JANCD-FCI
Swl :
Switch for selecting 9“ C R T o r E L d i s p l a y ( E L )
●
Model
Swl :
System number switch (16-position rotary
switch)
S w l [ 0 ] :
Normal operation mode
[1]:
End user parameter than ge mode
[4]:
Ladder edit mode
SW1 [2], [3], and [51 to [F] are
used only for maintenance.
Only
YASKAWA service personnel must
use these switches.
Model JANCD-FC230B or FC260
SW1 , SW2: Switches for selecting the panel and
external switches for–apply-ing power
1
2
3
S W 2 0 0 0
1
2
3
2
3
■
Model JANCD-FC31 O-1 (-2)
D / A v o l t a g e a d j u s t m e n t V R : A d j u s t e d a t t h e
f a c t o r y b e f o r e d e l i v e r y . R e a d j u s t m e n t i s
u n n e c e s s a r y .
VR1: First spindle gain adjustment
VR2: First spindle zero adjustment
(VR3: Second spindle gain adjustment).
spindle zero adjustment)
198