Checking Functions After Replacement

(a) Check that

and

outputs are not

shorted due to overloading.

(b) Apply the first power and second power again and

check that no alarm occurs.

(c) Check that switches on the machine control panel

can be operated.

6.2.1.4 9“

MONOCHROME GRAPHIC CRT

Removal

(a)

(b)

Check that AC input power is not supplied [the
SOURCE indication lamp (green ) of the power unit

is off], then pull out the cable connected to CNB of
model JANCD-FC900B.

Loosen the mounting screws and remove CRT from
the control panel.

(2) Installation

(a) Check the model and REV number of the replacement

module for consistency.

(b) Insert the cable to the original position.

(3)

Checking Functions After Replacement

(a) Check that

and

outputs are not

shorted due to overloading.

(b) Apply the first power and second power again and

check that no alarm occurs.

(c) Check that the brightness and contrast of the CRT

are normal.