4.3.2.2
DETAILS OF FUNCTION
M e m o r y C h e c k
Backup memory CMOS existing only in model JAN CD-
board and ROM/RAM memory on all CPU
boards are self-diagnosed.
Self-diagnosis includes items checked at system
startup and after startup.
( a )
( i )
CMOS Check
T o t a l C h e c k
Total check is made after system startup and CMOS
error is detected by total check sum on CMOS
memory.
This check is performed or not depending on the
system number.
a
A
I
Numbers checked . . .
I
When an error occurs in CMOS, the following alarms
are generated:
I
ALM109O: Setting total check error
ALM1091: Parameter total check error
ALM1092: Keep memory total check error
ALM1093: Offset total check error
ALM1094: Macro program variable total check
error
ALM1095: Processing program total check error
If an alarm occurs for some reason, CMOS data may
be destroyed.
The alarm can be erased by tempo-
rarily writing the data from the CRT control panel,
then depressing the
ESE
key on the control panel.
No alarm can be erased for processing programs.