2 indication of lamp of power supply unit – Yaskawa i80M Maintenance Manual User Manual

Page 137

Advertising
background image

4.4.2 INDICATION OF LAMP OF POWER SUPPLY UNIT

Table 4.45

Indication Lamp

I

Indication

Color

Meaning

SOURCE

Green

With this lamp on, AC input is executed or DC high
voltage will still be applied even if AC input OFF.

POWER ON

Green

Power on with normal DC output.

+5

Red

+5 V fault output

Red

V fault output

v

Red

+24 V fault output

E X T . A L A R M

Red

Alarm input from external power supply etc. is

4.4.3 CHECK DC POWER SUPPLY VOLTAGE

Measure at CN03 of model

or model

4 0

v 2

5

V 3

CN03

5

V :

Measure CN03 1-4

+12 V : Measure CN03 2-4
+24 V : Measure CN03 3-5