3 troubleshooting without alarm codes, Cent’d), 12 edit does not function – Yaskawa i80M Maintenance Manual User Manual

Page 132

Advertising
background image

4.3 TROUBLESHOOTING WITHOUT ALARM CODES

(Cent’d)

4.3.12 EDIT DOES NOT FUNCTION

Table 4.41

Edit Does Not Function

Cause of Trouble

Erroneous input signal

(a) The edit lock signal

is entered.

(b) The setting edit 10cI

signal is entered.

A

parameter to lock a

specially numbered
program is turned on.

Others:
(a) Memory capacity

exceeded

(b) Stored program

volume exceeded

(c) Overlapped stored

program

C h e c k M e t h o d

at 1/0 signal pm3007

= 1.

at setting pmOOOO

= 1.

OVER!

PROGRAM OVER!
ALREADY IN!

warning alarm is issued for each.

Solution

Select the edit lock release.
Set setting pmOOOO

to O.

For the procedure, refer to
YASNAC i80M Instruction
Manual
and YASNAC i80L
tion Manual (T0E-C843-
11.20).

This is a setting to prevent
programs from being
destroyed by erroneous edit
operation. For modification

parameters, refer to

i80M Instruction

Manual (TOE-C843-11.30)
and YASNAC i80L
tion Manual (T0E-C843-
11.20).

. Refer to YASNAC i80M

Instruction Manual

(TOE-C843-11.30) and
“ Part Program Editing”

of the YASNAC i80L

Instruction Manual

Continue the edit

operation after erasing
unnecessary programs.

124