Yaskawa i80M Maintenance Manual User Manual

Page 134

Advertising
background image

4.3

TROUBLESHOOTING WITHOUT ALARM CODES (Cent’d)

4.3.14 SKIP FUNCTION (G31 ) OPERATION FAILURE

Table

4.43

Skip Function (G31) Operation Failure

Cause of Trouble

Input failure of skip
signal

Model JANCD-FC230B
or

board is

wrong.

Parameter not set
correctly

Check Method

Jse 1/0 signal #3514 D

o

to D to confirm the

kip signal ON/OFF.

to

i80 Connecting Manual

‘arameter

pm2001

D

O

D

Use a transmission speed shown at

skip function

command time as

a speed set to parameter pm2440.

O: Use a transmission speed shown at

skip function

command time as

a speed assigned by the F code.

example, the machine does not work

the transmission speed is O at the

pm2440

command time.

D

O

t o

let a

signal mode shown at the start time of

he “SKIP” input for the D

o

skip function,

: When this parameter is set to “O”,

start the operation at the time of
change from 24 V to O V.

this parameter is set to “

I

”,

start the operation at the time of
change from O V to 24 V.

When this parameter is changed, turn

power on, then off again.

P a r a m e t e r

D

O

to

Determine ENABLE/DISABLE of an input
control circuit of “SKIP” for the skip
function.

1. When h

t e skip function is used, set

the bit to “l”.

2. When this parameter

changed,

turn power on, then off again.

Solution

Confirm operation of the

switches, etc.

Replace model
FC230B or FC260 board.
Contact your YASKAWA
represent ative.

Set the relevant
parameters correctly.

126