4 . 2

4.2.6

TROUBLESHOOTING BY ALARM CODES (Cent’d)

ALARMS

2071 TO 2078,2081 TO 2088

(REFERENCE POINT RETURN AREA ERROR)

Table 4.8

Cause of Trouble

This type of alarm results
when reference point
return performed
manually.
It also occurs by reference
point return at low speed

due to DECLS chattering.
Occurs at high speed by
error or reference point
pulse.

The alarm occurs at

automatic reference point
return.

Check Method

Observe DECLS chattering:
[/0 Signal

#3073

D

O

#3073

(2nd-axis)

#3073

(3rd-axis)

#3073

(4th-axis)

#3o73

(5th-axis)

#3073

(6th-axis)

#3073

(7th-axis)

#3073

(8th-axis)

Observe reference point pulse:
[/0 Signal
In case of i80M #3610

#3611

(2nd-axis)

#3612

(3rd-axis)

#3613

(4th-axis)

#3614

(5th-axis)

In case of i80L #3620

#3621

(2nd-axis)

#3622

(3rd-axis)

#3623

(4th-axis)

to to

#3627 D2 (8th-axis)

In case of G28 : Same as above

In case of G27 : Programmed position

differs from reference
point.

Solution

Adjustment of replacement

LS

Failure of module

Replace AC servo drive.
Replace FC300B board.

Replace AC motor.
Replace PG cable.

Same as above

Check the program.