Yaskawa G7 Modbus Communication User Manual

Page 63

Advertising
background image

63

Table 4.10 “H” Parameters

Access Level

Name

Address

Description

Data

Range

Unit

Default

During

Run

V/f

V/f

w/PG

OLV

FV

OLV2

0h 3-Wire

Control

1h Local/Remote

Selection

2h Option/Inverter

Selection

3h

Multi-Step Reference 1

4h

Multi-Step Reference 2

5h

Multi-Step Reference 3

6h

Jog Frequency Reference

7h Multi-Step

Accel/Decel 1

8h

External Baseblock NO

9h

External Baseblock NC

Ah

Accel/Decel Ramp Hold

Bh

OH2 Alarm Signal

Ch

Terminal A2 Enable

Dh

V/F w/ PG Disabled

Eh ASR

Integral

Reset

Fh

Terminal Not Used

(Set for Network Use)

10h MOP

Increase

11h MOP

Decrease

12h Forward

Jog

13h Reverse

Jog

14h Fault

Reset

15h Fast-Stop

N.O.

16h Motor

2

Selection

17h Fast-Stop

N.C.

18h Timer

Function

Input

19h PID

Disable

1Ah Multi-Step

Accel/Decel 2

1Bh Program

Lockout

1Ch

Trim Control Increase

1Dh

Trim Control Decrease

1Eh

Analog Frequency Reference

Sample Hold

20h

EFX- NO, Always, Ramp

21h

EFX- NC, Always, Ramp

22h

EFX- NO, Run, Ramp

23h

EFX- NC, Run, Ramp

24h

EFX- NO, Always, Coast

25h

EFX- NC, Always, Coast

26h

EFX- NO, Run, Coast

27h

EFX- NC, Run, Coast

28h EFX- NO, Always, Fast Stop

29h EFX- NC, Always, Fast Stop

2Ah

EFX- NO, Run, Fast Stop

2Bh

EFX- NC, Run, Fast Stop

2Ch

EFX- NO, Always, Alarm

2Dh

EFX- NC, Always, Alarm

2Eh

EFX- NO, Run, Alarm

2Fh

EFX- NC, Run, Alarm

30h

PID Integral Reset

31h

PID Integral Hold

32h Multi-Step Reference 4

34h PID

SFS

Cancel

H1-01 0400h

Digital Input Terminal S3

Function Selection

35h

Input Level Selection

1

24h - - - - -