TA Triumph-Adler P-C2660 MFP User Manual

Page 495

Advertising
background image

Troubleshooting

10-15

10

Error Code:3101

Is the server operating
correctly?

Make sure that the network
environment (server, hub, or other
LAN network) is operating correctly.

—

Is an authentication method
set for which the server
cannot respond normally?

Check the settings on the server and
client. (For example, make sure the
SMTP/POP authentication enable/
disable settings are the same on the
server and on the client.)

—

Error Code:3201

Is a non-supported SMTP
authentication method
enabled?

Check the SMTP authentication
settings on the server and client. The
SMTP authentication methods below
can be used on the machine.
CRAM-MD5 / DIGEST-MD5 / PLAIN /
LOGIN

—

Error Code:4201,
5101, 5102, 5103, 5104,
7101, 7102, 720f

–

Turn the main power switch off and
then on. If this occurs repeatedly,
write down the error code that
appears in the message display and
contact a service technician. (See the
procedure in

Machine failure. Call

service.

)

—

Error Code:9181

Have more than 999 original
pages been scanned?

If there are more than 999 original
pages, send the pages in separate
batches.

—

Error Message

Checkpoints

Corrective Actions

Reference

Page

Advertising
This manual is related to the following products: