PLANET WGSW-28040P User Manual

Page 31

Advertising
background image

User’s Manual of WGSW-28040 / 28040P / 28040P4

31

Approved PLANET SFP Transceivers

PLANET Managed Switch supports both 100Base-FX and 1000Base-SX/LX or Single mode and Multi-mode SFP transceiver.

The following list of approved PLANET SFP transceivers is correct at the time of publication:

Gigabit SFP Transceiver modules:

MGB-SX SFP (1000BASE-SX SFP transceiver / Multi-mode / 850nm / 220m or 550m)

MGB-LX SFP (1000BASE-LX SFP transceiver / Single mode / 1310nm / 10km)

MGB-L30 SFP (1000BASE-LX SFP transceiver / Single mode / 1310nm / 30km)

MGB-L50 SFP (1000BASE-LX SFP transceiver / Single mode / 1310nm / 50km)

MGB-LA10 SFP (1000BASE-LX SFP transceiver / WDM Single mode / TX: 1310nm, RX: 1550nm/ 10km)

MGB-LB10 SFP (1000BASE-LX SFP transceiver / WDM Single mode / TX: 1550nm, RX: 1310nm / 10km)

100Base-FX SFP Transceiver modules:

MFB-FX SFP (100BASE-FX SFP transceiver / Multi-mode / 1310nm / 2km)

MFB-F20 SFP (100BASE-FX SFP transceiver / Single mode / 1310nm / 20km)

MFB-FA20 SFP (100BASE-FX SFP transceiver / WDM Single mode / TX:1310nm, RX:1550nm / 20km)

MFB-FB20 SFP (100BASE-FX SFP transceiver / WDM Single mode / TX:1550nm, TX:1310nm / 20km)

It recommends using PLANET SFPs on the Managed Switch. If you insert a SFP transceiver that is

not supported, the Managed Switch will not recognize it.

Before connect the other Managed Switches, workstation or Media Converter.

1.

Make sure both side of the SFP transceiver are with the same media type, for example: 1000Base-SX to 1000Base-SX,

1000Bas-LX to 1000Base-LX.

2.

Check the fiber-optic cable type match the SFP transceiver model.

 To connect to 1000Base-SX SFP transceiver, use the Multi-mode fiber cable- with one side must be male duplex LC

connector type.

 To connect to 1000Base-LX SFP transceiver, use the Single-mode fiber cable-with one side must be male duplex LC

connector type.

Connect the fiber cable

1.

Attach the duplex LC connector on the network cable into the SFP transceiver.

2.

Connect the other end of the cable to a device – switches with SFP installed, fiber NIC on a workstation or a Media

Converter..

3.

Check the LNK/ACT LED of the SFP slot on the front of the Managed Switch. Ensure that the SFP transceiver is operating

correctly.

4.

Check the Link mode of the SFP port if the link failed. Co works with some fiber-NICs or Media Converters, set the Link

mode to “1000 Force” is needed.

Advertising
This manual is related to the following products: