Technical data - profibus, 2 technical data - profibus – ProSoft Technology ILX69-PBM User Manual

Page 113

Advertising
background image

ILX69-PBM ♦ CompactLogix or MicroLogix Platform

Contents

PROFIBUS Master Communication Module

User Manual

ProSoft Technology, Inc.

Page 113 of 124

February 4, 2015

Environmental Specifications

Environmental
Specifications Type

Measurements

Value

Emission

Radiated Emission E-Field

DIN EN 61131-2; CISPR 16, EN 55011

Conducted Emission

DIN EN 61131-2; CISPR16, EN55011

Immunity

Immunity to Electrostatic
Discharge (ESD)

DIN EN 61131-2; IEC 61000-4-2

Immunity to Burst

DIN EN 61131-2; IEC 61000-4-4

Immunity to Surge

DIN EN 61131-2; IEC 61000-4-5

Immunity to Radiated
Electromagnetic Field

DIN EN 61131-2; IEC 61000-4-3

Immunity to Conducted RF

DIN EN 61131-2; IEC 61000-4-6

Climate Test

Dry Heat Withstand

DIN EN 61131-2; Clause 6.2, DIN EN 60068; -2-2 Bb

Cold Withstand

DIN EN 61131-2; Clause 6.2, DIN EN 60068; -2-1 Ab

Dry Heat Immunity

DIN EN 61131-2; Cl. 12.1.5 / 11.6, DIN EN 60068; -2-2 Bd

Cold Immunity

DIN EN 61131-2; Cl. 12.1.5 / 11.6, DIN EN 60068; -2-1 Ad

Mechanical Test

Vibration Sinusoidal

DIN EN 61131-2; Clause 6.3.1, DIN EN 60068;

–2-6 Fc

Shock Test

DIN EN 61131-2; Clause 6.3.2, DIN EN 60068;

–2-27 Ea

8.2

Technical Data - PROFIBUS

Parameter

Description

Maximum number of supported DPV0/DPV1 slaves 125 slaves

Maximum number of total cyclic input data

5712 bytes (Status information is separately managed)

Maximum number of total cyclic output data

5760 bytes

Maximum number of cyclic input data

244 bytes per slave

Maximum number of cyclic output data

244 bytes per slave

Configuration data maximum

244 bytes per slave

Parameterization data per slave

7 bytes/slave standard parameters
237 bytes/slave application specific parameters

Acyclic communication DPV1

Class 1 Read/Write
DPV1 Class 1 Alarm
DPV1 Class 2 Initiate/Read/Write/Data transport/Abort

Maximum number of acyclic read/write

240 bytes per slave

Functions

Configuration in Run

Redundancy function

Supported (Requires host application program support)

Baud rate

9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud,
187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12
Mbaud. Auto-detection mode is not supported.

Data transport layer

PROFIBUS FDL

Limitations

DPV2 isochronous mode and slave-to-slave communication are
not supported.
The redundancy function is not supported.

Reference to firmware/stack version

V2.6.x.x

Advertising