DPV1 Alarm Response

This message is used to send a DPV1 Alarm Response to a slave device. The message
acknowledges the alarm when the appropriate indication appears in the DPV1 Alarm
indication area. The information mapped to this area must be used in the DPV1 Alarm
Response message in order to process the alarm properly. The mapping of this information
is as follows.

ILX69PBM.CONTROL.DPV1.Alarm.Request.

Parameter

Data Type Value

Description

Status

DINT

0x0000

ILX69-PBM Status

Command

DINT

0x221C

Command code

SlaveAddress

SINT

0 to 125

Slave address causing the alarm

AlarmType

SINT

0 to 255

Type of alarm

SlotNumber

SINT

0 to 255

Slot number of slave causing the alarm

Specifier

SINT

0 to 255

Alarm specifier

Function

SINT

0

Reserved, set to 0

Reserved

SINT

-

N/A

ILX69PBM.CONTROL.DPV1.Alarm.Response.

Parameter

Data Type Value

Description

Status

DINT

ILX69-PBM Status. 0 = OK

Command

DINT

0x221D

Command code

SlaveAddress

SINT

0 to 125

Slave address causing the alarm

AlarmType

SINT

0 to 255

Type of alarm

SlotNumber

SINT

0 to 255

Slot number of slave causing the alarm

Specifier

SINT

0 to 255

Alarm specifier

Function

SINT

0

Reserved, set to 0

ErrorDecode

SINT

0 to 255

A value of 128 indicates a DPV1 error

ErrorCode1

SINT

0 to 255

DPV1 Error code 1

ErrorCode2

SINT

0 to 255

DPV1 Error code 2