ProSoft Technology ILX69-PBM User Manual

Page 77

Advertising
background image

ILX69-PBM ♦ CompactLogix or MicroLogix Platform

Contents

PROFIBUS Master Communication Module

User Manual

ProSoft Technology, Inc.

Page 77 of 124

February 4, 2015

6.2.3 Output Array

Device Command Registers

Bytes 0 to 3 contain the Device Command Registers. They are transferred from the
controller to the module via the output region.

Device Command Registers

Byte
Offset

Structure
Member

Data
Type

Description

0

MCB

SINT

Module Command Bits, see table below

1

HSR

SINT

Handshake Request Bits

2

BTO

INT

Block Transfer Out

3

BTI

INT

Block Transfer In

Module Command Bits

Bit
Offset

Structure
Member

Data
Type

Description

0

Reserved

BOOL

Reserved, set to 0

1

Reserved

BOOL

Reserved, set to 0

2

Reserved

BOOL

Reserved, set to 0

3

Reserved

BOOL

Reserved, set to 0

4

Reserved

BOOL

Reserved, set to 0

5

NRDY

BOOL

Application Not Ready

6

Reserved

BOOL

Reserved, set to 0

7

RST

BOOL

Reset


NRDY

– Not Ready

Using this bit, the user program can start or stop the PROFIBUS network communications.
When communications stop, all slaves go to fail safe mode and the master goes to Stop
mode.
RST

– Reset

Using this bit, the user program can reset (Cold boot) the ILX69-PBM.

Important: Using the Reset command will cause an interruption in bus
communication. All connected slaves will go to fail safe mode.