ILX69-PBM ♦ CompactLogix or MicroLogix Platform

Contents

PROFIBUS Master Communication Module

User Manual

ProSoft Technology, Inc.

Page 97 of 124

February 4, 2015

Parameter

Description

Range of
Value/Value

General Diagnostics

Communication Error

Shows the communication error code. If the cause of the error is
resolved, the value will be set to zero again.
All possible numbers are listed in [1].

0x00000000 to
0xFFFFFFFF

Error Counter

Counter; counts up for each error event.

0x00000000 to
0xFFFFFFFF

Watchdog Time

The Watchdog time determines the time frame in which the
device watchdog must be re-triggered from the CompactLogix
program while the CompactLogix program monitoring is
activated. When the watchdog time value is equal to 0, the
watchdog is deactivated and the CompactLogix program
monitoring is deactivated also.

The permissible range of values of the watchdog time is 20 to
65535 ms. The default watchdog time is 1000 ms. With a
watchdog time, the software watchdog is deactivated.

20 to 65535 ms
Default: 1000 ms