2
On the shortcut menu, select C
HOOSE
M
ODULE
T
YPE
. This action opens the
Choose
Module Type
dialog box.
3
In the Product Line Filter area of the dialog box, select MVI56E. In the Select Module
Type
dropdown list, select MVI56E-DNPNET, and then click OK
to save your settings
and return to the ProSoft Configuration Builder window.
3.5
Connecting Your PC to the Module
3.5.1 Using CIPconnect
®
to Connect to the Module
You can use CIPconnect
®
to connect a PC to the ProSoft Technology MVI56E-DNPNET
module over Ethernet using Rockwell Automation’s 1756
-ENBT EtherNet/IP
®
module. This
allows you to configure the MVI56E-DNPNET network settings and view module diagnostics
from a PC. RSLinx is not required when you use CIPconnect. All you need are:
The IP addresses and slot numbers of any 1756-ENBT modules in the path
The slot number of the MVI56E-DNPNET in the destination ControlLogix chassis (the
last ENBTx and chassis in the path).
To use CIPconnect, follow these steps.
1
In the tree view in ProSoft Configuration Builder, right-click the MVI56E-DNPNET icon to
open a shortcut menu.