General Settings Page for X-ANC

1.

The General Settings page shows the connected accessory port.

2. Accessory Name – displays the editable name for this accessory.
3. Connected Port ID, and location of the accessory on the port wiring bus. (Port A, position 3.)
4. Import Settings – allows a saved configuration file to be imported to duplicate an existing setup.
5. Export Settings – saves the configuration file as a backup or to use for importing.
6. Reset Settings – allows selecting between: Reset to default values or Reset parameters and reboot accessory.
8. The locate icon can be clicked on or off causing the connected device to flash to physically identify its location. If left on, it will automatically shut

off after 30 minutes or will cancel when the controller encoder is used.

7.

The ANC processing data is shown in real time along with a button to unassign the ANC from the assigned Zone.

8. A jump button takes you directly to the assigned zone ANC settings page to make adjustments. From the ANC settings page it also has a link on

the sensor noise level meter “>” that returns you to this Accessory page.

Plug and Play Accessories Connection Rules

To guarantee good performance of all connected accessories, follow these rules:
1.

Use CAT5e or CAT6 non-shielded cable (see cabling section) to connect accessories to the host processor bus-ports.

2. Up to 8 accessories can be daisy chained from a single port.
3. The “IN” port is connected to the upstream device (AZM or another accessory). (see image rule 3)
4. The maximum cable length from the AZM to the last accessory on the chain is 1000’(305m). (see image rule 4)
5. One audio wall plate (A-XLR, A-RCA, A-BT) can be used per bus-port. (see image rule 5)
6. Up to 16 accessories can be connected to a single AZM. (see image rule 6)
7.

Up to 12 QR code virtual controllers can be used in addition to wired accessories.

Image Rule 3

Advertising