Panasonic TH-65SQ1WA 65" Class 4K HDR Commercial Monitor User Manual

Page 79

Advertising
background image

79

English

[User name]
Enter the user name for authentication with one-byte

alphanumeric characters (excluding space). (Up to 64

characters)
This can be set only when [EAP] is set to items other

than [None] or [EAP-TLS].

[Password]

Enter the password for authentication with one-byte

alphanumeric characters. (Up to 64 characters)
This can be set only when [EAP] is set to items other

than [None] or [EAP-TLS].

Note

For 98 and 86 inch models, [EAP], [User name]

and [Password] are displayed only when the main

software version is 4.0000 or later.

When EAP is used, this unit needs to be configured

according to the settings of the RADIUS server.
For the settings of the RADIUS server, consult with

the network administrator.

When [EAP] is set to [EAP-TLS], set [Date and time]

(see page 76) and register the certificate on the WEB

browser control. (see page 103)

[MAC address]

Displays the MAC address of this unit.

[Network status]

Checks the current Network settings status.

192. 168. 0. 1

255. 255. 255. 0

192. 168. 0. 8

12:34:56:78:9A:BC

Network status

DHCP
IP address
Subnet mask
Gateway
EAP

Off

None

MAC address

Note

For 98 and 86 inch models, [EAP] is set only when

the main software version is 4.0000 or later.

[DIGITAL LINK mode]

Switches communication method of DIGITAL LINK

terminal.

[Auto]:

Communication method is selected automatically.
HDMI, LAN, serial communication are possible.
Ethernet connection is possible.

[DIGITAL LINK]:

HDMI, LAN, serial communication are possible via a

twisted pair cable transmitter.

[Ethernet]:

LAN communication is possible via the LAN terminal

of the display.

[Long reach]:

Communication method is fixed to Long reach.

Modes allowing communication

:

Valid

― :

Invalid

Settings

Communication validity

Picture

transmission Ethernet RS-

232C

100 m 150 m

Auto

For

DIGITAL

LINK

For Long

reach

For

Ethernet

DIGITAL LINK

Long reach

Ethernet

Note

When connected with the [Long reach]

communication method, the maximum

transmission distance is 150 m. In this case, this

unit can receive the signals of up to 1080/60p

(148.5 MHz).

If the communication method of the twisted

pair cable transmitter is set to [Long reach], set

[DIGITAL LINK mode] to [Auto]. Then, connection

is enabled with the [Long reach] communication

method.
When connecting with the separately sold DIGITAL

LINK Switcher (ET-YFB200G) with the [Long

reach] communication method, set [DIGITAL LINK

mode] to [Long reach].

Even if [DIGITAL LINK mode] is set to [Long

reach], when the twisted pair cable transmitter

does not support the communication method of

[Long reach], it will not be connected properly.