Conformance with ul/c-ul standard, About the manuals – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 10

Advertising
background image



A - 9

CONFORMANCE WITH UL/C-UL STANDARD


(1) Servo amplifiers and servo motors used

Use the servo amplifiers and servo motors which comply with the standard model.

Servo amplifier series :MR-J2S-10CP to MR-J2S-700CP

MR-J2S-10CP1 to MR-J2S-40CP1

Servo motor series

:HC-KFS

HC-MFS

HC-SFS

HC-RFS

HC-UFS

HA-LFS

HC-LFS


(2) Installation

Install a cooling fan of 100CFM (2.8m

3

/min) air flow 4 [in] (10.16 [cm]) above the servo amplifier or

provide cooling of at least equivalent capability.


(3) Short circuit rating

This servo amplifier conforms to the circuit whose peak current is limited to 5000A or less. Having
been subjected to the short-circuit tests of the UL in the alternating-current circuit, the servo
amplifier conforms to the above circuit.


(4) Capacitor discharge time

The capacitor discharge time is as listed below. To ensure safety, do not touch the charging section for
15 minutes after power-off.

Servo amplifier

Discharge time [min]

MR-J2S-10CP(1) 20CP(1) 1

MR-J2S-40CP(1) 60CP 2

MR-J2S-70CP to 350CP

3

MR-J2S-500CP 700CP 5


(5) Options and auxiliary equipment

Use UL/C-UL standard-compliant products.


(6) Attachment of a servo motor

For the flange size of the machine side where the servo motor is installed, refer to “CONFORMANCE
WITH UL/C-UL STANDARD” in the Servo Motor Instruction Manual.


(7) About wiring protection

For installation in United States, branch circuit protection must be provided, in accordance with the
National Electrical Code and any applicable local codes.
For installation in Canada, branch circuit protection must be provided, in accordance with the Canada
Electrical Code and any applicable provincial codes.


<<About the manuals>>

This Instruction Manual and the MELSERVO Servo Motor Instruction Manual are required if you use
the MR-J2S-CP for the first time. Always purchase them and use the MR-J2S-CP safely.

Relevant manuals

Manual name

Manual No.

MELSERVO-J2-Super Series To Use the AC Servo Safely

IB(NA)0300010

MELSERVO Servo Motor Instruction Manual

SH(NA)3181

EMC Installation Guidelines

IB(NA)67310

Advertising