3 - 35

3. SIGNALS AND WIRING

(c) Alarm occurrence

Electromagnetic brake

Dynamic brake

Electromagnetic brake

Dynamic brake

(ON)

Forward
rotation

Electromagnetic
brake interlock (MBR)

Servo motor speed

Base circuit

Trouble (ALM)

ON

OFF

ON

OFF

(Note)

0r/min

No

Yes (OFF)

Electromagnetic brake

operation delay time

(10ms)

Note. ON: Electromagnetic brake is not activated.

OFF: Electromagnetic brake is activated.

(d) Both main and control circuit power supplies off

(10ms)

(10ms)

Electromagnetic brake

operation delay time

(Note 1)

15 to 60ms

Electromagnetic brake

Dynamic brake

Electromagnetic brake

Dynamic brake

(ON)

Forward
rotation

Electromagnetic
brake interlock (MBR)

Servo motor speed

Base circuit

Trouble (ALM)

ON

OFF

ON

OFF

(Note 2)

0r/min

No

Yes (OFF)

Main circuit

Control circuit

power

ON

OFF

Note 1. Changes with the operating status.

2. ON: Electromagnetic brake is not activated.

OFF: Electromagnetic brake is activated.